37
in.xm
SC - ER
System learning error
Every time a low-level option is changed, system must “learn”
currents associated to each output/load. During this learning
process, the device connected to Di (direct output, no relay) must
be disconnected IF IT DRAWS MORE THAN 0.4 AMP. If it isn’t,
system will report an SC error code.
• Disconnect load.
• Restart learning process by pressing Select key for 5 sec.
• Press Change key as many times as necessary to go through all
low level programming settings (see low level programming
section).
• When process is done, the accessory connected to Di can
be reconnected.
Keypad doesn’t seem to work!
Note: Keypad connected to in.xm is only detected when main
breaker is reset. Don’t forget to reset breaker if you’re changing
keypad model (in.k400 for in.k600).
If a keypad doesn’t seem to work:
• Verify keypad connections and try spare keypad.
• Replace keypad if problem is corrected.
• Replace in.xm if problem is not corrected.
Keypad connections
accessories corrective actions