in.xm accessories corrective actions
BL - ER
Blower not responding
Make sure blower is connected properly.
Manually change the output status (on/off) of blower.
Reset spa pack.
If error does not clear, problem is probably with blower, it will
need to be replaced.
If blower is replaced, a new learning routine must be performed
(see procedure page 15).
FN - ER
Fan not responding
Make sure fan is properly connected.
Manually change the output status (on/off) of fan.
Reset spa pack.
If error does not clear, problem is probably with the fan.
It will need to be replaced.
If the fan is replaced, a new learning routine must be performed
(see procedure page 15).
Replace ozonator par Fan.
Important:
If the fan doesn't draw more than 400 ma, the FN-ER error will
not be displayed even if the fan is defective.