SP - HR
Internal hardware error detected in in.xm
Restart the spa pack and start & stop all pumps and blower.
If error reappears, replace in.xm spa pack.
SP - BR
Incorrect input current con guration setting
Increase in.xm current rating and breaker setting.
Increase breaker size and manufacturer's cable gauge or reduce
pump size.
SP-Br is not considered an error code, therefore it doesn’t trigger
the service icon to appear on display. Although SP-Br should be
viewed more as a warning, it wont allow the heater or any other
accessory to come on if the amperage available is not adequate for
the requirements.